Oscilloscope Mode (Vertical) Frequency Response - DC Coupled Without probes and test leads (with

Quantity
Add to wish list
Product description



  Oscilloscope Mode (Vertical)

  Frequency Response - DC Coupled

  Without probes and test leads (with BB120): DC to 40 MHz (-3 dB)

  With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB)

  With VP41 10:1 probe: DC to 40 MHz (-3 dB)

  Frequency Response - AC Coupled (LF Roll Off)

  Without probes and test leads: <10 Hz (-3 dB)

  With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB)

  With VP41 10:1 probe: <10 Hz (-3 dB)

  Rise Time, Excluding Probes, Test Leads

  <8.75 ns

  Input Impedance

  Without probes and test leads: 1 MΩ/20 pF

  With BB120: 1 MΩ/24 pF

  With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF

  With VP41 10:1 probe: 5 MΩ/15.5 pF

  Sensitivity

  5 mV to 200 V/div

  Analog Bandwidth Limiter

  10 kHz

  Display Modes

  A, -A, B, -B

  Maximum Input Voltage A and B

  Direct, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage

  With BB120: 600 Vrms

  Maximum Floating Voltage, from any Terminal to Ground

  600 Vrms CAT IV, 750 Vrms up to 400 Hz

  Oscilloscope Mode (Horizontal)

  Scope Modes

  Normal, single, roll

  Ranges (Normal)

  Equivalent sampling: 10 ns to 500 ns/div

  Real time sampling: 1 μs to 5 s/div

  Single (real time): 1 μs to 5 s/div

  Roll (real time): 1 s to 60 s/div

  Sampling Rate (for Both Channels Simultaneously)

  Equivalent sampling (repetitive signals): up to 4 GS/s

  Real time sampling 1 μs to 60 s/div: 40 MS/s

  Trigger

  Screen Update

  Free run, on trigger

  Source

  A, B

  Sensitivity A and B

  At DC to 5 MHz: 0.5 divisions or 5 mV

  At 40 MHz: 1.5 divisions

  At 60 MHz: 4 divisions

  Slope

  Positive, negative

  Advanced Scope Functions

  Display Modes

  Normal: Captures up to 25 ns glitches and displays analog-like persistence waveform

  Smooth: Suppresses noise from a waveform

  Glitch off: Does not capture glitches between samples

  Envelope: Records and displays the minimum and maximum of waveforms over time

  Auto Set (Connect-and-View)

  Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level

  Input A and B

  DC Voltage (V DC)

  Ranges: 500 mV, 5, 50, 500, 750 V

  Accuracy: ±(0.5% +5 counts)

  Common mode rejection (CMRR): >100 dB at DC, >60 dB at 50, 60, or 400 Hz

  Full scale reading: 5000 counts

  True RMS Voltages (V AC and V AC+DC)

  Ranges: 500 mV, 5, 50, 500, 750 V

  Accuracy for 5 to 100% of range (DC coupled)

  DC to 60 Hz (V AC + DC): ±(1% +10 counts)

  1 to 60 Hz (V AC): ±(1% +10 counts)

  Accuracy for 5 to 100% of range (AC or DC coupled): 60 Hz to 20 kHz: ±(2.5% +15 counts)

  DC rejection (only V AC): >50 dB

  Common mode rejection (CMRR): >100 dB at DC; >60 dB at 50, 60, or 400 Hz

  Full scale reading: 5000 counts, reading is independent of any signal crest factor

  Peak

  Modes: Maximum peak, minimum peak, peak-to-peak

  Ranges: 500 mV, 5, 50, 500, 2200 V

  Accuracy: Maximum peak or minimum peak: 5% of full scale; peak-to-peak: 10% of full scale

  Full scale reading: 500 counts

  Frequency

  Ranges: 1, 10, 100 Hz, 1, 10, 100 kHz, 1, 10, and 70 MHz

  Frequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset

  Accuracy at 1 Hz to 1 MHz: ±(0.5% +2 counts)

  Full scale reading: 10,000 counts

  RPM

  Maximum reading: 50 kRPM

  Accuracy: ±(0.5% +2 counts)

  Duty Cycle

  Range: 2 to 98%

  Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset

  Pulse Width

  Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset

  Full scale reading: 1000 counts

  Amperes

  With current clamp

  Ranges: same as V DC, V AC, V AC+DC, or peak

  Scale factors: 0.1, 1, 10, 100, 400 mV/A, 1 V/A, 10 mV/mA

  Accuracy: same as V DC, V AC, V AC+DC, or peak (add current clamp uncertainty)

  Decibel

  0 dBV: 1 V

  0 dBm (600/50 Ω): 1 mW referenced to 600 or 50 Ω

  dB on V DC, V AC, or V AC+DC

  Full scale reading; 1000 counts

  Crest Factor

  Range: 1 to 10

  Full scale reading: 90 counts

  Phase

  Modes: A to B, B to A

  Range: 0 to 359°

  Resolution: 1°

  Power

  Configurations: 1 phase/3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)

  Power factor (PF): Ratio between watts and VA range - 0.00 to 1.00

  Watt: RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes); Full scale reading: 999 counts

  VA: Vrms x Arms; Full scale reading: 999 counts

  VA reactive (var): √((VA)2-W2); Full scale reading: 999 counts

  Vpwm

  Purpose: To measure on pulse width modulated signals, like motor drive inverter outputs

  Principle: Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency

  Accuracy: As Vrms for sine wave signals

  Input A to Common

  Ohm

  Ranges: 50, 500 Ω, 5, 50, 500 kΩ, 5, 30 MΩ

  Accuracy: ±(0.6% +5 counts) 50 Ω ±(2% +20 counts)

  Full scale reading: 50 Ω to 5 MΩ - 5000 counts; 30 MΩ - 3000 counts

  Measurement current: 0.5 mA to 50 nA, decreases with increasing ranges

  Open circuit voltage: <4 V

  Common Continuity (Cont)

  Beep: <(30 Ω ±5 Ω) in 50 Ω range

  Measurement current: 0.5 mA

  Detection of shorts of: ≥1 ms

  Common Diode

  Measurement voltage: At 0.5 mA: >2.8 V

  At open circuit: <4 V

  Measurement current: 0.5 mA

  Polarity: + on input A, - on COM

  Capacitance (CAP)

  Ranges: 50, 500 nF, 5, 50, 500 μF

  Full scale reading: 5000 counts

  Measurement current: 500 nA to 0.5 mA, increases with increasing ranges

  Advanced Meter Functions

  Zero Set

  Set actual value to reference

  AutoHold (on A)

  Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals

  Fixed Decimal Point

  Activated by using attenuation keys

  Cursor Readout

  Sources

  A, B

  Single Vertical Line

  Average, minimum and maximum readout

  Average, minimum, maximum and time from start of readout (in ROLL mode; instrument in HOLD)

  Minimum, maximum and time from start of readout (in RECORDER mode; instrument in HOLD)

  Harmonics values in POWER QUALITY mode

  Dual Vertical Lines

  Peak-peak, time distance and reciprocal time distance readout

  Average, minimum, maximum and time distance readout (in ROLL mode; instrument in HOLD)

  Dual Horizontal Lines

  High, low and peak-peak readout

  Rise or Fall Time

  Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode)

  Accuracy

  As oscilloscope accuracy

  Recorder

  Meter Readings

  Measurement speed: Maximum 2 measurements

  Record size (minimum, maximum, average): 2 M readings for 1 channel

  Recorded time span: 2 weeks

  Maximum number of events: 1024

  Waveform Record

  Maximum sample rate: 400 K samples

  Size internal memory: 400 M samples recorded time

  Span internal memory: 15 minutes at 500 μs/div - 11 hours at 20 ms/div

  Record size SD card: 1.5 G samples

  Recorded time span SD card: 11 hours at 500 μs/div - 14 days at 20 ms/div

  Maximum number of events: 64

  Power Quality

  Readings

  Watt, VA, var, PF, DPF, Hz

  Watt, VA, Var Ranges (Auto)

  250 W to 250 MW, 625 MW, 1.56 GW

  When selected: total (%r) ±(2% + 6 counts)

  When selected: fundamental (%f) ±(4% + 4 counts)

  DPF

  0.00 to 1.00

  PF

  0 to 1, ±0.04

  Frequency Range

  10 Hz to 15 kHz

  40 to 70 Hz

  Number of Harmonics

  DC to 51

  Readings/Cursor Readings

  (Fundamental 40 to 70 Hz)

  Vrms/Arms /Watt

  Each harmonic from fundamental maybe selected for individual readings

  Bus Health Tester

  AS-i

  Subtype: NEN-EN50295

  CAN

  Subtype: ISO-11898

  Interbus S

  Subtype: RS-422

  Protocol: EIA-422

  Modbus

  Subtype: RS-232; Protocol: RS-232/EIA-232

  Subtype: RS-485; Protocol: RS-485/EIA-485

  Foundation Fieldbus

  Subtype: H1

  Protocol: 61158 type 1, 31.25 kBit

  Profibus

  Subtype: DP; Protocol: EIA-485

  Subtype: PA; Protocol: 61158 type 1

  RS-232

  Subtype: EIA-232

  RS-485

  Subtype: EIA-485

  General Specifications

  Waveform Display

  Vertical: 10 div of 40 pixels

  Horizontal: 12 div of 40 pixels

  Maximum Input Voltage A and B

  Direct on input or with leads: 600 Vrms CAT IV for derating

  With banana-to BNC adapter BB120: 600 Vrms for derating

  Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz

  Display

  Type: 5.7" color active martrix TFT

  Resolution: 640 x 480

  Interface

  Optically isolated: Transfer screen copies (bitmaps), settings and data

  USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®

  Wireless Radio with Adapter

  Frequency range: 2412 to 2462 MHz

  Output power: <100 mW

  Environmental

  MIL-PRF-28800F, Class 2

  Temperature

  Battery operation: 32 to 104°F (0 to 40°C)

  Power adapter operation: 32 to 122°F (0 to 50°C)

  Storage: -4 to 140°F (-20 to 60°C) non-condensing

  Humidity (Operating)

  At 32 to 50°F (0 to 10°C): non-condensing

  At 50 to 86°F (10 to 30°C): 95%

  At 86 to 104°F (30 to 40°C): 75%

  At 104 to 122°F (40 to 50°C): 45%

  Altitude

  Operating at 10,000' (3 km): CAT III 600 V

  Operating at 6600' (2 km): CAT IV 600 V

  Storage: 40,000' (12 km)

  EMC Electromagnetic Compatibility

  USA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103)

  Enclosure Protection

  IP51, ref: EN/IEC60529

  Safety

  General: IEC 61010-1: Pollution Degree 2

  Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V

  Memory

  Internal memory can store 20 data sets (screen waveform and setup)

  Micro SD card slot with optional SD card (maximum size of 32 GB)

  Power

  External: Via power adapter BC430

  Input voltage: 10 to 21 V DC

  Consumption: 5 W typical

  Input connector: 5 mm jack

  Internal: Via battery pack BP290

  Battery power: Rechargeable Li-Ion 10.8 V

  Operating time: 7 hours with 50 % backlight brightness

  Charging time: 4 hours with test tool off, 7 hours with test tool on

  Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging

  Dimensions

  10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)

  Weight

  3.2 lbs (1.4 kg) including battery pack